Sampling Details | |||
---|---|---|---|
Sub Type: Hotel/motel | Special Feature: | Location: | |
Area: 490 | Volume (gallons): 12795 | Flow measure reading (gpm): 45 | Minimum required flow (gpm): 27 |
Disinfectant: Salt | Secondary Disinfectant: | ORP: 676 | Turnover Rate (min): 284 |
Total Chlorine (ppm): 3 | Free Chlorine (ppm): 2.5 | Combined Chlorine (ppm): 0.5 | Total Bromine (ppm): 0 |
Alkalinity (ppm): 110 | Pool water temp ˚F: 81 | pH: 7.3 | Cyanuric acid (ppm): 0 |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
No critical violations were documented at the time of inspection.
No violations were documented at the time of inspection.
Comments |
---|
The disinfectant residuals and water quality parameters meet code requirement. The recommended range is 2-4 ppm. Make sure the free chlorine stays above 1.0 ppm. -pH was measured at 7.3. -All required safety equipment was provided. -The pool perimeter was secure. -The filter pressure was 10 psi. -Turn over rate was 285 minutes. - The facility uses salt and acid to create chlorine. Therefore the pool is disinfected using chlorine. - ACC tests recorded monthly. Thanks. - Pool records properly recorded. - ORP at 676mv, pH on ACC at 7.40pH. No violations noted. Keep up the good work. Ensure total chlorine is recorded daily. If you have any questions or concerns, call Bela Perler at 513-732-7612. |