Sampling Details | |||
---|---|---|---|
Sub Type: Hotel/motel | Special Feature: | Location: | |
Area: 490 | Volume (gallons): 12795 | Flow measure reading (gpm): 0 | Minimum required flow (gpm): 74 |
Disinfectant: Salt | Secondary Disinfectant: | ORP: 757 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 3 | Free Chlorine (ppm): 3 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 80 | Pool water temp ˚F: 82 | pH: 7.4 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 74 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(1)(a) / Outlet covers are installed/secured/in compliance
Critical VGB drain covers (Aquastar P9101, five (5) year replacement) are at the facility, but have not been placed on the drains.
Install the covers on the two (2) main drains. 3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat The filter system flow meter is not working.
Repair the flow meter so water turnover rates can be determined.
Comments |
---|
Pool Notes: 1. Pressure gauge reads 21psi. 2. Auto Controller pH reads 7.6. 3. The salt system was replaced. Information was updated in the Inventory Sheet. Inspection conducted by Scott Bradley,R.S. 732-7614 |