Sampling Details | |||
---|---|---|---|
Sub Type: Apartment/Condo | Special Feature: | Location: | |
Area: 880 | Volume (gallons): 26400 | Flow measure reading (gpm): 80 | Minimum required flow (gpm): 55 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: | Turnover Rate (min): 480 |
Total Chlorine (ppm): 5 | Free Chlorine (ppm): 5 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 100 | Pool water temp ˚F: 78 | pH: 7.4 | Cyanuric acid (ppm): 10 |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(6)(q) / Depth markers/deck warning signs are maintained
Repeat Depth markers were not maintained in a clearly visible manner.
Repaint the depth markers so that they are easily visible.
Comments |
---|
1. Pool disinfectants meet all code requirements. 2. Pool water was clear 3. First aid and life saving equipment were provided. 4. The pressure on filter gauge was noted at 9 psi. 5. Pool fence was secure. 6. Turnover Rate is 330 minutes. If there are any questions call, Mackinzie Dickman at 513-732-7602. |