Sampling Details | |||
---|---|---|---|
Sub Type: Spray Ground | Special Feature: | Location: | |
Area: 706 | Volume (gallons): 1200 | Flow measure reading (gpm): 60 | Minimum required flow (gpm): |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 710 | Turnover Rate (min): 20 |
Total Chlorine (ppm): 0.2 | Free Chlorine (ppm): 0.2 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 30 | Pool water temp ˚F: 69 | pH: 7.0 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(4) / The licensee /authorized representative is keeping records
The licensee /authorized representative was not keeping or maintaining operational records.
All facility records must be maintained and available for review upon request.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8. pH observed at 7.0
Treat the pool water so that the pH is within the acceptable range.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm. Alkalinity noted at 30ppm.
Raise the total alkalinity to at least 60 ppm.
3701-31-04 (D)(8) / Acceptable test kit provided/adequate/in good repair
Acceptable test kit was not provided.
Obtain a test kit that can accurately indicate the water quality of the swimming pool.
3701-31-04(D)(6)(a)(6) / Spray ground free chlorine disinfectant residual shall be above 2 ppm.
Critical Spray ground free chlorine disinfectant residual was below 2 ppm. Chlorine residual noted at 0.2ppm. Ensure that residual is maintained at a minimum of 2ppm.
Do not operate the sprayground until the chlorine disinfectant is at 2 ppm or above.
Comments |
---|
1. Ensure that pH is raised to range of 7.2-7.8. 2. Chlorine noted at 0.2; ensure that level is raised to 2ppm prior to opening spray ground. 3. Alkalinity is to be minimum 60ppm. One or more of the critical violations noted on this report may pose an imminent health hazard. Operator voluntarily closed the pool. Pool is to remain closed and posted as such, until the following violations: Spray ground free chlorine residual shall be above 2 ppm, are corrected |