Sampling Details
Sub Type: Wading Pool Special Feature: Location:
Area: 100 Volume (gallons): 780 Flow measure reading (gpm): 20 Minimum required flow (gpm): 6.5
Disinfectant: Sodium Hypochlorite Secondary Disinfectant: ORP: Turnover Rate (min): 39
Total Chlorine (ppm): 4 Free Chlorine (ppm): 3.5 Combined Chlorine (ppm): 0.5 Total Bromine (ppm):
Alkalinity (ppm): 40 Pool water temp ˚F: 79 pH: 7.3 Cyanuric acid (ppm):
Spa water temp ˚F: Spa water replaced every 30 days: Max Allow. Filter Flow (gpm): Max Allow. Flow: Jet pump capacity (gpm):
Max Allow. Flow: SF pump capacity (gpm):
[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(4)(a)(iv) / Water temperatures are recorded daily
Water temperatures were not being recorded daily.
Take and record the water temperature at least once/day.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.


Inspection Information


[?] Facility Type: Pool

[?] Inspection Type: Standard

[?] Inspection Date: 01-July-2020

Comments
Pool looks clear
Perimeter is able to prevent unauthorized entry
Chemicals are well balanced
Ensure to raise alkalinity
Keep up the great work!

Any questions contact Michael at 513-560-6177