Sampling Details
Sub Type: Apartment/Condo Special Feature: Location:
Area: 750 Volume (gallons): 22500 Flow measure reading (gpm): 80 Minimum required flow (gpm): 47
Disinfectant: Sodium Hypochlorite Secondary Disinfectant: ORP: Turnover Rate (min): 280
Total Chlorine (ppm): 10 Free Chlorine (ppm): 10 Combined Chlorine (ppm): 0 Total Bromine (ppm):
Alkalinity (ppm): 120 Pool water temp ˚F: 72 pH: 7.4 Cyanuric acid (ppm):
Spa water temp ˚F: Spa water replaced every 30 days: Max Allow. Filter Flow (gpm): 113 Max Allow. Flow: Jet pump capacity (gpm):
Max Allow. Flow: SF pump capacity (gpm):
[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1) / Public swimming pool shall operate free of an imminent health hazard.
Critical The outside gate is not self latching.
Ensure that the outside gate is self latching. The outside gate was secured and only the inside entrance is going to be used until the gate is fixed.


Inspection Information


[?] Facility Type: Pool

[?] Inspection Type: Standard

[?] Inspection Date: 03-June-2015

Comments
1. The outside gate was secured until it can be made self latching..
2. Disinfectant residual is much higher than necessary. However, it meets minimum code requirements at this time.
3. Water quality readings meet minimum code requirements at this time.
4. The filter pressure gauge was noted at 4 psi.
5. The pool water was clear.
If you have any questions or concerns, call me at (513) 732-7612.