Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1440 | Volume (gallons): 43200 | Flow measure reading (gpm): 90 | Minimum required flow (gpm): 90 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 636 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 3 | Free Chlorine (ppm): 3 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 100 | Pool water temp ˚F: 80 | pH: 7.6 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 141 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
The pool entrance gate does not latch when closed.
Repair the gate so it will latch when closed. Correct By: 17-Jul-2014 3701-31-04 (D)(7)(c) / Audible/visual alarm when unit is malfunctioning or when pH or ORP levels are not acceptable.
The ACC unit automatic shut off did not work.
Determine a way to test the unit shut off. Correct By: 17-Jul-2014 3701-31-04 (E)(2)(a)(ii) / A USCG Type IV personal flotation device with 30 -60 foot throw line provided
A USCG Type IV personal flotation device with 30 -60 foot throw line was not provided at the unguarded pool.
Provide a proper floatation device at all times. Correct By: 17-Jul-2014 3701-31-04 (E)(2)(d) / First aid kit provided
There are no gloves in the first aid kit.
Provide disposable gloves in the first aid kit. Correct By: 17-Jul-2014
Comments |
---|
Pool Notes: 1. Filter pressure gauge noted at 12psi. 2. Turnover rate=8 hours. 3. ACC pH noted at 7.5. 4. The pool water was clear Inspection conducted by Scott Bradley,R.S. 732-7614 |