Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1650 | Volume (gallons): 51000 | Flow measure reading (gpm): 120 | Minimum required flow (gpm): 110 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 785 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 2 | Free Chlorine (ppm): 2 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 120 | Pool water temp ˚F: 83 | pH: 7.6 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 141 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Repeat Weirs are missing from the skimmers. Replace the missing weirs.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation.
Comments |
---|
No other violations observed during the inspection. The pool otherwise looks great! Pool Notes: 1. The pool water is clear. 2. ACC unit pH noted at 7.4. 3. Turnover rate=7.1 hours. 4. Pool filter pressure gauge noted at 12psi. 4. All safety equipment is available. 5. ACC unit alarm functions when tested. Testing is documented in pool records. 6. The report was emailed to Swim Safe Pools. Contact Scott Bradley, R.E.H.S. (732-7614) with any questions. |