Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1800 | Volume (gallons): 54000 | Flow measure reading (gpm): | Minimum required flow (gpm): 113 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: | Turnover Rate (min): 480 |
Total Chlorine (ppm): 3 | Free Chlorine (ppm): 3 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 130 | Pool water temp ˚F: 85 | pH: 7.6 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(4)(a)(ii) / Combined chlorine is tested daily at pool side prior to use
Repeat Combined chlorine was not tested daily at pool side prior to use.
Test and record the pool Combined Chlorine at least every four (4) hours during operation.
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat One (1) shallow end skimmer basket weir is missing.
Replace the missing weir.
Comments |
---|
No other violations observed during the inspection. The pool looks great Pool Notes: 1. The pool water is clear. 2. Upon arrival, the wading pool was being back washed. Therefore, the turnover rate could not be determined. 3. One (1) lifeguard was on duty during the inspection. 4. The 2015 pool license is posted. Inspection conducted by Scott Bradley,R.S. 732-7614 |