Sampling Details
Sub Type: Wading Pool Special Feature: Location:
Area: 136 Volume (gallons): 1530 Flow measure reading (gpm): 30 Minimum required flow (gpm): 13
Disinfectant: Sodium Hypochlorite Secondary Disinfectant: ORP: 725 Turnover Rate (min):
Total Chlorine (ppm): 6 Free Chlorine (ppm): 6 Combined Chlorine (ppm): 0 Total Bromine (ppm):
Alkalinity (ppm): 450 Pool water temp ˚F: 84 pH: 8.4 Cyanuric acid (ppm): 0
Spa water temp ˚F: Spa water replaced every 30 days: Max Allow. Filter Flow (gpm): Max Allow. Flow: Jet pump capacity (gpm):
Max Allow. Flow: SF pump capacity (gpm):
[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(2) / Authorized representative is on-site or within 30 minutes of pool location
Authorized representative was not on-site or within 30 minutes of pool location.
Make arrangements to have an authorized representative available while pool is in operation.
3701-31-04 (B)(4)(a)(ii) / Combined chlorine is tested daily at pool side prior to use
Repeat Combined chlorine was not tested daily at pool side prior to use.
Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the combined chlorine must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use.
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Repeat Main gate to pool entrance was not self-closing.
Repair gates or doors in order to be self-closing and lockable. Correct By: 16-Jul-2019
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH was outside the range of 7.2 to 7.8. pH observed at 8.4
Treat the pool water so that the pH is within the acceptable range.
3701-31-04 (E)(2)(d) / First aid kit provided
Repeat First aid kit did not contain gloves.
Provide first aid kit complete with gloves.


Inspection Information


[?] Facility Type: Pool

[?] Inspection Type: Standard

[?] Inspection Date: 15-July-2019

Comments
Pool is hearby ordered closed due to the following safety threat: main gate is not self-closing. Pool is to remain closed and posted as such, until the gate violation is corrected, and verified in writing by this office.

Pool water is clear and disinfectant residuals met minimum code requirements at this time.
During inspection, ACC alarm was observed for high pH. Acc recorded pH at 8.5
Inspector recorded pH at 8.4.
ORP observed at 725 mv.
Alkalinity was also observed high at 450ppm.
Safety equipment and signs were available.
Reinspection of gate will be conducted 7/16.
Pool looks good.