Sampling Details | |||
---|---|---|---|
Sub Type: School | Special Feature: | Location: | |
Area: 1800 | Volume (gallons): 65000 | Flow measure reading (gpm): 200 | Minimum required flow (gpm): 168 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 690 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 5 | Free Chlorine (ppm): 5 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 30 | Pool water temp ˚F: 90 | pH: 7.5 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity measured at 30 ppm was less than the minimum reading of 60 ppm specified by code.
Raise the total alkalinity to at least 60 ppm. NOTE: The National Swimming Pool Foundation (NSPF) recommends maintaining Total Alkalinity at 80-120 ppm with a target reading of 100 ppm.
Comments |
---|
Pool inspection notes: Disinfectant residual and water quality readings meet minimum code requirements at this time. Water clarity is excellent. Pool has two (2) large unblockable custom fabricated drains in the deep end of the pool. Recommend replacing pool reagents annually (mark received by date on reagents or kit to keep track). ACC tested during inspection. Visual no flow alarm activated; chemical feed pumps deactivated as required. Pool looks great! |