Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1000 | Volume (gallons): 30000 | Flow measure reading (gpm): 60 | Minimum required flow (gpm): 60 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 606 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 4 | Free Chlorine (ppm): 4 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 120 | Pool water temp ˚F: 84 | pH: 7.5 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 75 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 ( D )(6)(a) / ORP reading is above 650 mv
The ACC unit ORP was noted at 606mv.
Increase the ACC unit ORP to 650mv minimum. Correct By: 23-Jul-2014 3701-31-04 ( D )(6)(a) / ORP reading is above 650 mv
ORP reading was noted at 606 mv.
Increase the ACC unit ORP to 650mv minimum. Correct By: 23-Jul-2014 3701-31-04 (B)(1)(a) / Outlet covers are installed/secured/in compliance
Critical Specifications are not available for the two (2) main drain covers.
Provide specifications (Manufacturer, Model#, Install and Replacement dates) for the main drain covers. Correct By: 23-Jul-2014 3701-31-04 (D)(7)(c) / Audible/visual alarm when unit is malfunctioning or when pH or ORP levels are not acceptable.
The ACC unit alarm could not be tested.
Determine a way to test the ACC unit alarm. Correct By: 23-Jul-2014 3701-31-04 (D)(7)(c) / Audible/visual alarm when unit is malfunctioning or when pH or ORP levels are not acceptable.
The ACC unit alarm could not be tested.
Determine a way to test the ACC unit alarm. Correct By: 23-Jul-2014 3701-31-04 (E)(2)(d) / First aid kit provided
First aid kit does not have sufficient items to control bleeding or disposable gloves.
Provide these items in the first aid kit. Correct By: 23-Jul-2014
Comments |
---|
Pool Notes: 1. Turnover rate=8 hours. 2. ACC unit pH noted at 7.3 3. The pool pH was between 7.4-7.6 4. The pool water was clear Inspection conducted by Scott Bradley,R.S. 732-7614 |