Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1325 | Volume (gallons): 39750 | Flow measure reading (gpm): 95 | Minimum required flow (gpm): |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: | Turnover Rate (min): 418 |
Total Chlorine (ppm): 2 | Free Chlorine (ppm): 2 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 120 | Pool water temp ˚F: 83 | pH: 7.5 | Cyanuric acid (ppm): 0 |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(4)(a)(iv) / Water temperatures are recorded daily
Repeat Water temperatures were not being recorded daily.
Take and record the water temperature at least once/day.
3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
Repeat ACC test results/ service records were not maintained.
The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results.
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 (B)(6)(o)/Ladders/stairs/steps are in good repair/slip resistent Ladder rail on the shallow side of the pool and the ladder on the left side of the pool (towards pump room) was not secured properly to the pool deck surface. Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair. |
3701-31-04 (B)(6)(s)/Perimeter barrier is in good repair to prevent unauthorized entry The black gate in the rear end of pool will close with force but it is not self latching. Repair the gate, so that it is both self closing and self latching. |
3701-31-04 (C)(2)/pH is within 7.2 to 7.8 The pH was noted at 7.9. Ideal range is 7.2 to 7.8. Treat the pool water so that the pH is within the acceptable range. |
3701-31-04 (E)(2)(b)(i)/12 ft. non-telescopic reach pole with Sheppard's crook & a USCG Type IV personal flotation device with 30 - 60 foot throw line. The reach pole provided was telescopic. Provide 12 ft. non-telescopic reach pole with Shepherd's crook. |
3701-31-04 (E)(2)(d)/First aid kit provided First aid equipment was not provided. Provide first aid equipment, including a first aid kit, at the pool at all times. |
Comments |
---|
Thanks for correcting all critical violation. Please ensure water temperature(every day) and ACC test results are recorded (monthly once) on the daily log. |