Sampling Details | |||
---|---|---|---|
Sub Type: Wading Pool | Special Feature: | Location: | |
Area: 225 | Volume (gallons): 2531 | Flow measure reading (gpm): 40 | Minimum required flow (gpm): 21 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 772 | Turnover Rate (min): 120 |
Total Chlorine (ppm): 3 | Free Chlorine (ppm): 3 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 40 | Pool water temp ˚F: 85 | pH: 7.2 | Cyanuric acid (ppm): 0 |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 60 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(6)(q) / Depth markers/deck warning signs are maintained
Repeat Depth markers/deck warning signs were not maintained in a clearly legible/visible manner.
Repaint / reapply at least two (2) depth markers around the perimeter of the wading pool in accordance with code requirements so that bathers are able to clearly see the depth of the water. NOTE: "No Diving" signs are not required at wading pools.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity reading of 40 ppm was less than the 60 ppm minimum required by code.
Raise the total alkalinity to at least 60 ppm.
Comments |
---|
Facility inspection notes: Water clarity, disinfectant residuals, pH, and daily pool operation records meet minimum code requirements at this time. Pool looks good at this time. Thanks for a good 2016 pool season. |