Sampling Details
Sub Type: Wading Pool Special Feature: Location:
Area: 225 Volume (gallons): 2531 Flow measure reading (gpm): 40 Minimum required flow (gpm): 21
Disinfectant: Sodium Hypochlorite Secondary Disinfectant: ORP: 772 Turnover Rate (min): 120
Total Chlorine (ppm): 3 Free Chlorine (ppm): 3 Combined Chlorine (ppm): 0 Total Bromine (ppm):
Alkalinity (ppm): 40 Pool water temp ˚F: 85 pH: 7.2 Cyanuric acid (ppm): 0
Spa water temp ˚F: Spa water replaced every 30 days: Max Allow. Filter Flow (gpm): 60 Max Allow. Flow: Jet pump capacity (gpm):
Max Allow. Flow: SF pump capacity (gpm):
[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6)(q) / Depth markers/deck warning signs are maintained
Repeat Depth markers/deck warning signs were not maintained in a clearly legible/visible manner.
Repaint / reapply at least two (2) depth markers around the perimeter of the wading pool in accordance with code requirements so that bathers are able to clearly see the depth of the water. NOTE: "No Diving" signs are not required at wading pools.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity reading of 40 ppm was less than the 60 ppm minimum required by code.
Raise the total alkalinity to at least 60 ppm.


Inspection Information


[?] Facility Type: Pool

[?] Inspection Type: Standard

[?] Inspection Date: 16-August-2016

Comments
Facility inspection notes:
Water clarity, disinfectant residuals, pH, and daily pool operation records meet minimum code requirements at this time.
Pool looks good at this time. Thanks for a good 2016 pool season.