Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1000 | Volume (gallons): 30000 | Flow measure reading (gpm): 80 | Minimum required flow (gpm): 63 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 669 | Turnover Rate (min): 375 |
Total Chlorine (ppm): 3 | Free Chlorine (ppm): 3 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 100 | Pool water temp ˚F: 73 | pH: 7.4 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Observed pipe in pump room leaking into bucket.
Ensure leak is repaired. 3701-31-04 (B)(6)(l) / Secondary means of entrapment/evisceration prevention is provided
Observed the equalizer line in skimmer basket by basket ball hoop to not be plugged.
Ensure that equalizer line is plugged by re-inspection.
Comments |
---|
Notes: -Safety equipment available. -Pool clear and meets code requirements. -Reinspection to ensure that equalizer line by basket ball hoop is plugged. |