Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1800 | Volume (gallons): 54000 | Flow measure reading (gpm): 80 | Minimum required flow (gpm): 113 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: | Turnover Rate (min): 480 |
Total Chlorine (ppm): 2.5 | Free Chlorine (ppm): 2.5 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 110 | Pool water temp ˚F: 77 | pH: 7.4 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical The main drain covers were installed in May 2009 with a seven (7) year (May 2016) life span.
Replace the covers to verify VGB compliance.
3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Total alkalinity was not tested weekly.
Test and record total alkalinity at least once per week.
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat A 3' and 5' skimmer basket weir were missing.
Replace the missing weirs.
3701-31-04 (B)(6)(k) / Outlet drain covers are secure/meet ANSI/ASME A112.19.8-2007 requirements.
Critical The main drain covers were installed in May 2009 with a seven (7) year (May 2016) life span.
Replace the covers to verify VGB compliance.
3701-31-04 (D)(8) / Acceptable test kit provided/adequate/in good repair
Corrected During Inspection Reagents for testing alkalinity (Reagents 7,8, and 9) were not available.
Provide reagents to test pool water alkalinity.
Comments |
---|
No other violations observed during the inspection. Pool Notes: 1. The pool water is clear. 2. Wading pool turnover rate noted at 11.25 hours. For an eight (8) hour turnover rate, a flow rate of 113gpm is recommended. 3. One (1) lifeguard was on duty during the inspection. 4. The 2017 pool license is posted. 5. The report was emailed to Mr. Henke Inspection conducted by Scott Bradley,R.S. 732-7614 |