Sampling Details | |||
---|---|---|---|
Sub Type: Hotel/motel | Special Feature: | Location: | |
Area: 418 | Volume (gallons): 12500 | Flow measure reading (gpm): 50 | Minimum required flow (gpm): 26 |
Disinfectant: Salt | Secondary Disinfectant: | ORP: 775 | Turnover Rate (min): |
Total Chlorine (ppm): 4 | Free Chlorine (ppm): 4 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 90 | Pool water temp ˚F: 81 | pH: 7.6 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. Missing skimmer weirs.
All equipment must be maintained in accordance with the manufacturers specifications.
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 (E)(2)(d)/First aid kit provided First aid equipment was not provided. Provide first aid equipment, including a first aid kit, at the pool at all times. Ensure first aid kit is stocked with gloves. |
3701-31-04(D)(6)(a)(2)/Pool free chlorine disinfectant residual shall be above 1 ppm. Pool free chlorine disinfectant residual was noted at 0 ppm. Do not operate the pool until the chlorine disinfectant residual is at 1 ppm or above. |
3701-31-04 (D)(7)(d)/Flow or pressure switch with a shut off valve shall be provided and tested monthly. Flow or pressure switch for a shut off valve was not provided or the unit was not tested monthly Have the ACC unit serviced or replaced with a unit that has a flow or pressure switch with an automatic shut off valve. Provide records indicating that the unit is being tested monthly. |
Comments |
---|
Inspection Notes: 1. Follow up inspection conducted on 1/20/2023. 2. First aid kit was properly stocked. 3. Chlorine levels met required standards. |