Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1650 | Volume (gallons): 51000 | Flow measure reading (gpm): 70 | Minimum required flow (gpm): 110 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 730 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 2.5 | Free Chlorine (ppm): 2.5 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 70 | Pool water temp ˚F: 81 | pH: 7.6 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 141 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Weirs are missing from the skimmer baskets. Replace the missing weirs.
All equipment must be maintained in accordance with the manufacturers specifications. 3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
The pool water turnover rate was noted at twelve (12) hours. Increase the flow rate of the circulation system to 110gpm to maintain a eight (8) hour water turnover rate.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve. 3701-31-04 (E)(3)(d) / "WARNING or DANGER - POOL CLOSED" sign(s) posted-when the pool is closed
The "WARNING or DANGER - POOL CLOSED" sign could not be located. Provide a sign stating "WARNING or DANGER - POOL CLOSED".
Post the "WARNING or DANGER - POOL CLOSED" sign at all times the pool is not available for use.
Comments |
---|
Pool Notes: 1. The pool water is clear. 2. ACC unit pH noted at 7.5. 3. Turnover rate=12 hours. 4. All safety equipment is available. 5. ACC unit alarm functions when tested. Testing is documented in pool records. 6. The report was emailed to Swim Safe. Contact Scott Bradley, R.S (732-7614) with any questions. |