Sampling Details | |||
---|---|---|---|
Sub Type: Apartment/Condo | Special Feature: | Location: | |
Area: 880 | Volume (gallons): 26400 | Flow measure reading (gpm): | Minimum required flow (gpm): |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: | Turnover Rate (min): |
Total Chlorine (ppm): 2.5 | Free Chlorine (ppm): 2.5 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): | Pool water temp ˚F: | pH: 7.3 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (A) / All construction or alterations of a public swimming pool are approved
Repeat The installation of the "Stingl" switch could not be determined to be approved.
An equipment replacement notification report was given to the operator. Submit the form to ODH for approval and keep for records.
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 (B)(6)(s)/Perimeter barrier is in good repair to prevent unauthorized entry The gate near the pump room is not self latching. The gate was locked. The gate is going to stay locked until it is self latching. |
3701-31-04 (E)(2)(a)(i)/12 ft. non-telescopic reach pole with shepherd's crook is provided The 12 ft. reach pole with shepherd's crook is telescopic. Ensure the pole is non-telescoping. |
3701-31-04 (B)(4)(c)/SVRS/APSOS/ACC test results/ service records are maintained SVRS test results/ service records were not maintained. The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results. |
3701-31-04 (B)(6)(c)(v)/Discharge of water from a public swimming pool shall be in accordance with OEPA. Water from the pool was not being discharged to a sanitary sewage system. It is discharged outside to a gravel bed. Provide documentation that the method of water discharge is approved by the OEPA. |
Comments |
---|
1. Thank you for the corrections! 2. The drain covers are SDX High Flow Safety Drain 10". The drains are VGB compliant and have a five year service life. 3. The wading pool had a pH of 7.2 and a free chlorine level of 9. 4. A Stingl switch was installed in addition to the Vac Alert system by Cincinnati Pool Management, Inc. The redundant system installation has created confusion. In addition, the wading pool as two VGB compliant drains three feet apart and has a Vac Alert system. |