Sampling Details
Sub Type: Other Special Feature: Location:
Area: 1800 Volume (gallons): 54000 Flow measure reading (gpm): 120 Minimum required flow (gpm): 113
Disinfectant: Sodium Hypochlorite Secondary Disinfectant: ORP: 750 Turnover Rate (min): 480
Total Chlorine (ppm): 6 Free Chlorine (ppm): 6 Combined Chlorine (ppm): 0 Total Bromine (ppm):
Alkalinity (ppm): 60 Pool water temp ˚F: 84 pH: 7.3 Cyanuric acid (ppm):
Spa water temp ˚F: Spa water replaced every 30 days: Max Allow. Filter Flow (gpm): 74 Max Allow. Flow: Jet pump capacity (gpm):
Max Allow. Flow: SF pump capacity (gpm):
[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Repeat Specifications have not been provided for the main drain cover.
Provide specifications for the main drain cover (Install/Replace dates) to verify VGB compliance.
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
The filter pressure gauges do not appear to be working.
Repair the gauges so pool filter pressure can be monitored.
3701-31-04 (B)(6)(k) / Outlet drain covers are secure/meet ANSI/ASME A112.19.8-2007 requirements.
Critical Repeat Specifications have not been provided for the main drain cover.
Provide specifications for the main drain cover (Install/Replace dates) to verify VGB compliance.


Inspection Information


[?] Facility Type: Pool

[?] Inspection Type: Standard

[?] Inspection Date: 14-July-2017

Comments
No other violations observed during the inspection.
The pool otherwise looks great!
Pool Notes:
1. The 2017 pool license is posted.
2. The pool water is clear.
3. Proper safety equipment is available for use.
4. ACC unit and SVRS device testing is documented in the pool records.
5. Pool turnover rate=7.5 hours.
6. The pool pH was between 7.2-7.4
7. The report was emailed to Ms. Michelson.