Sampling Details | |||
---|---|---|---|
Sub Type: Apartment/Condo | Special Feature: | Location: | |
Area: 1500 | Volume (gallons): 42374 | Flow measure reading (gpm): 55 | Minimum required flow (gpm): 88 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: | Turnover Rate (min): |
Total Chlorine (ppm): 3.5 | Free Chlorine (ppm): 3.5 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): | Pool water temp ˚F: | pH: 7.3 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 74 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(4) / The licensee /authorized representative is keeping records
Repeat The licensee /authorized representative was not keeping or maintaining operational records.
All facility records must be maintained and available for review upon request. 3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat One skimmer weir was missing.
Replace the missing skimmer weir. 3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Repeat The fence near the shallow end of the pool is broken can be deflected to create a gap greater than 4 inches.
Repair the perimeter barrier so that there are not any gaps greater than 4 inches anywhere along the barrier.
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 (B)(1)(d)/Circulation/Disinfection system shall operate properly. Initially the filters were being bypassed (no filtration). After attempting to correct the flow, one filter seemed to be stuck in backwash. The operators were unable to restore proper flow or circulation the pool. Ensure proper flow and circulation is restored to the pool |
Comments |
---|
During the inspection circulation was restored to both filters. Pressure was measured at 7 and 10 psi in the filters. Flow was measured at 100 gpm. A follow-up is scheduled to ensure the fence is repaired. |