Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1440 | Volume (gallons): 43200 | Flow measure reading (gpm): 90 | Minimum required flow (gpm): 90 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 684 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 5 | Free Chlorine (ppm): 5 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 130 | Pool water temp ˚F: 83 | pH: 7.7 | Cyanuric acid (ppm): 0 |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 141 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Repeat Total alkalinity was not tested weekly.
Test and record total alkalinity at least once/week. 3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
pH probe indicates the pool pH is 6.8 while the measured pH of the pool water is 7.7.
Clean and recalibrate the pH probe so that it gives an accurate pH value. All equipment must be maintained in accordance with the manufacturers specifications. 3701-31-04 (E)(2)(a)(ii) / A USCG Type IV personal flotation device with 30 -60 foot throw line provided
The 30-60 foot throw line was not attached to the USCG Type IV personal flotation device at the unguarded pool.
Attach the throw rope to the PFD so that a distressed / drowning swimmer can be rescued without the need to enter the pool. 3701-31-04 (E)(2)(d) / First aid kit provided
Adhesive bandage supply is depleted in the first aid kit.
Replenish the supply of adhesive bandages in the first aid kit. 3701-31-04 (E)(3)(b) / "Children must be supervised" or "Swimming alone is not recommended" signs posted
Repeat The unguarded pool was in use without the "Swimming alone is not recommended" sign posted as required.
Post the "Swimming Alone is Not Recommended" sign at all times the pool is open for use.
Comments |
---|
Facility inspection notes: Water clarity disinfectant residuals and water quality readings meet minimum code requirements at this time. Onsite records indicate that the ACC pressure and pump shut off switches were tested the week of 7/24-7/30. Another 30-day test is due this week. Pool looks good at this time. Thanks for your time and efforts this 2016 pool season. Drain covers are not due for replacement until 2018. Reminder: pool records must be retained for 2 years. Restrooms are clean and properly supplied. |