Sampling Details
Sub Type: Other Special Feature: Location:
Area: 1800 Volume (gallons): 54000 Flow measure reading (gpm): 120 Minimum required flow (gpm): 113
Disinfectant: Sodium Hypochlorite Secondary Disinfectant: ORP: Turnover Rate (min):
Total Chlorine (ppm): 0 Free Chlorine (ppm): 0 Combined Chlorine (ppm): 0 Total Bromine (ppm):
Alkalinity (ppm): Pool water temp ˚F: pH: 7.7 Cyanuric acid (ppm):
Spa water temp ˚F: Spa water replaced every 30 days: Max Allow. Filter Flow (gpm): Max Allow. Flow: Jet pump capacity (gpm):
Max Allow. Flow: SF pump capacity (gpm):
[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Repeat The entrance gate is self closing, but will not stay latched.
Repair the entrance gate so it will self close and latch. In addition, upon arrival the entrance gate was open (Gate was secured to the wall with a bungee cord. The gate must be kept closed to prevent unwanted access to the pool. Correct By: 30-Jun-2015
3701-31-04 (D)(02) / Public swimming pool is continuously disinfected using a chemical feeding device connected to the circulation system
Critical Upon arrival, the lifeguard (Bruce) stated bottles of shock are being used to disinfect the pool.
Repair or replace the disinfection system so that the pool is continuously being disinfected. Mr. Rich agreed to Voluntarily Close the Pool (Sign is Posted). Correct By: 30-Jun-2015
3701-31-04(D)(6)(a)(2) / Pool free chlorine disinfectant residual shall be above 1 ppm.
Critical The pool free chlorine disinfectant residual was noted at 0 ppm.
Raise and maintain the pool free chlorine residual at 1.0ppm minimum. Mr. Rich agreed to voluntarily close the pool until a free chlorine residual of 1.0ppm is maintained. Correct By: 30-Jun-2015


Inspection Information


[?] Facility Type: Pool

[?] Inspection Type: Standard

[?] Inspection Date: 24-June-2015

Comments
Pool Notes:
1. Mr. Rich agreed to Voluntarily Close the Pool (Sign is Posted) until a free chlorine residual of 1.0ppm is maintained.
2. The pH was between 7.6-7.8.
Inspection conducted by Scott Bradley,R.S. 732-7614