Inspection Information | Facility Name: | FINDLAY FAMILY YMCA - EAST POOL |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 11-October-2017 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(6)(q) Depth markers/deck warning signs were not maintained in a clearly legible/visible manner. Depth markers were missing at the ends of the pool. Replace the depth markers/deck warning signs so that bathers are able to clearly see the depth of the water and that no diving is permitted where clearly indicated. Depth markers must be located no farther than 25 feet apart and must be at least 4 inches in size. Depth should reflected to nearest 6 inch or 1/2 foot. |
3701-31-04 (D)(7)(d) Critical Flow switch for a shut off valve was not working correctly and the unit was not tested monthly Have the ACC unit serviced or replaced with a unit that has a flow or pressure switch with an automatic shut off valve. Provide records indicating that the unit is being tested monthly. |
Comments |
---|
Free chlorine, combined chlorine, ph, water clarity, water temperature must be tested prior to bather entry and at least every 12 hours while open for use. A follow up inspection will be conducted 11/16/17 to observe depth markers and flow switch repaired |