Inspection Information | Facility Name: | COMFORT SUITES POOL |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 03-October-2019 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 ( D )(6)(a) ORP reading was below 650 mv (AT TIME OF INSPECTION THE OPR READING WAS 568) Have the ACC unit inspected to determined why the ORP is low. |
3701-31-04 (B)(4)(a)(i) Repeat Disinfection residuals were not tested daily at pool side and/or at the required intervals for pools/automatic chemical controllers/special features.(AT TIME OF INSPECTION IT WAS OBSERVED THAT ON MANY DAYS NO POOL CHEMISTRY WAS BEING PERFORMED - TO INCLUDE THE CURRENT WEEK BEGINNING 9/29) Test the disinfection residual every day before bathers enter the water. Disinfection residual must then be tested every 4 hours when an ACC is not in use. If an ACC is in use the disinfectant residual must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the disinfectant residual must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use. |
3701-31-04 (B)(4)(a)(ii) Repeat Combined chlorine was not tested daily at pool side prior to use.(AT TIME OF INSPECTION IT WAS OBSERVED THAT ON MANY DAYS NO POOL CHEMISTRY WAS BEING PERFORMED - TO INCLUDE THE CURRENT WEEK BEGINNING 9/29) Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the combined chlorine must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use. |
3701-31-04 (B)(4)(a)(iii) Repeat pH was not tested daily at pool side and/or at required intervals for pools/automatic chemical controllers/special features. (AT TIME OF INSPECTION IT WAS OBSERVED THAT ON MANY DAYS NO POOL CHEMISTRY WAS BEING PERFORMED - TO INCLUDE THE CURRENT WEEK BEGINNING 9/29) pH must be tested prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use pH must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the pH must be tested at 1 special feature every 6 hours the sprayground or spray feature is in use. |
3701-31-04 (B)(4)(a)(iv) Water temperatures were not being recorded daily.(AT TIME OF INSPECTION IT WAS OBSERVED THAT ON MANY DAYS NO POOL CHEMISTRY WAS BEING PERFORMED - TO INCLUDE THE CURRENT WEEK BEGINNING 9/29) Take and record the water temperature at least once/day. |
3701-31-04 (B)(4)(c) Repeat SVRS/APSOS/ACC test results/ service records were not maintained. (AT TIME OF INSPECTION IT WAS OBSERVED THAT THE AUTOMATIC CHEMICAL CONTROLLER (ACC) IS NOT BEING TESTED AND DOCUMENTED ON THE OPERATION REPORT) The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results. |
3701-31-04 (B)(6)(h) Required meters and gauges were not maintained or were not functional while the pool is in operation. (AT TIME OF INSPECTION THE FLOW METER WAS NOT FUNCTIONING CORRECTLY - THE FLOW METER HAD BEEN DISLODGED FROM POSITION AND WAS NOT CAPABLE OF READING THE FLOW ON THE POOL) Maintain all meters and gauges in a properly funtioning manner at all times while the pool is in operation. |
3701-31-04(D)(6)(a)(2) Critical Pool free chlorine disinfectant residual was below 1 ppm. (AT TIME OF INSPECTION THE FREE CHLORINE WAS .5 ppm) Do not operate the pool until the chlorine disinfectant residual is at 1 ppm or above. |
Comments |
---|
THE POOL MUST BE CLOSED UNTIL THE CRITICAL VIOLATION OF THE DISINFECTION RESIDUAL IS CORRECTED. A POOL REQUIRES A MINIMUM OF 1.0 ppm OF FREE CHLORINE TO OPERATE. |