Inspection Information | Facility Name: | LAKEVIEW POOL & TENNIS CLUB SPA |
---|---|
Facility Type: | Spa |
[?] Inspection type: | Standard |
Inspection date: | 15-August-2014 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(1)(c) Critical Chlorine disinfectant residual was less than 2 ppm for the spa Do not operate the pool when the disinfectant residuals are less than what is required. Ensure the chlorine disinfectant residual is at 2 ppm or above prior to placing the spa back into operation. |
3701-31-04 (B)(4)(a)(i) Disinfection residuals were not tested before opening Test the disinfection residual every day before bathers enter the water. If an ACC is in use the disinfectant residual must be tested every 12 hours while the pool is in use. |
3701-31-04 (B)(4)(a)(iii) pH was not tested before opening. pH must be tested prior to bathers entering the water must be tested every 12 hours while the spa is in use. |
3701-31-04 (C)(2) pH was outside the range of 7.2 to 7.8. (<6.8) Treat the spal water so that the pH is within the acceptable range. |
Comments |
---|
Spa was draining and will be re-filled. Correctly balance chemicals before re-opening. |