Inspection Information | Facility Name: | DRURY INN & SUITES |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 28-June-2017 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(6)(c)(ii) Corrected During Inspection Backwash lines and lines from drainage sumps did not have an air gap prior to discharge (AT TIME OF INSPECTION THERE WAS A CROSS CONNECTION BETWEEN DRAIN LINES AND DRAIN) Open the lines that discharge into the backwash or drainage sumps so that there is an air gap and the lines can drain freely. (THE UPSIDE DOWN BUCKETS CAN ONLY BE USED TO PREVENT SPLASH AT THE TIME OF DRAINING AND THEN MUST BE IMMEDIATELY REMOVED. |
3701-31-04 (B)(6)(o) Ladders/stairs/steps were not in good repair or were not slip resistant. (AT TIME OF INSPECTION THE FOLLOWING POOL LADDERS WERE LOOSE: ALL 3 OUTDOOR LADDERS AND THE ONE INTERIOR LADDER LOCATED AT THE 5 FOOT MARKER NEAREST THE SPA) Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair. (TIGHTEN LADDERS) |