Inspection Information | Facility Name: | BPOE ELKS LODGE #75 - WADING |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 17-June-2021 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(4)(a)(i) Disinfection residuals were not tested daily at pool side and/or at the required intervals for pools/automatic chemical controllers/special features. Test the disinfection residual every day before bathers enter the water. Disinfection residual must then be tested every 4 hours when an ACC is not in use. If an ACC is in use the disinfectant residual must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the disinfectant residual must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use. |
3701-31-04 (B)(4)(a)(ii) Combined chlorine was not tested daily at pool side prior to use. Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the combined chlorine must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use. |
3701-31-04 (B)(4)(a)(iii) pH was not tested daily at pool side and/or at required intervals for pools/automatic chemical controllers/special features. pH must be tested prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use pH must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the pH must be tested at 1 special feature every 6 hours the sprayground or spray feature is in use. |
3701-31-04 (B)(6)(s) Gates or doors were not self-closing and lockable.(AT TIME OF INSPECTION THE GATE TO THE MAIN POOL FAILS TO SELF LATCH EVERY TIME. THIS GATE MUST LATCH EVERYTIME TO PREVENT ACCIDENTAL DROWNING) Repair gates or doors in order to be self-closing and lockable. |
Comments |
---|
Ensure that staff is testing wading pool at required 4 hour intervals and documenting. |