Inspection Information | Facility Name: | BPOE ELKS LODGE #75 - WADING |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 19-July-2017 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(4)(a)(ii) Combined chlorine was not tested daily at pool side prior to use. (THE TESTING FOR COMBINE CHLORINE IS NOT BEING DONE CORRECTLY) Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the combined chlorine must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use. (AT TIME OF INSPECTION CORRECT WAT TO TEST FOR COMBINED CHLORINE WAS DISCUSSED WITH LIFE GUARD. FOLLOW INSTRUCTIONS ON TEST KIT) |
3701-31-04 (B)(4)(a)(vii) Cyanuric acid was not tested weekly. (CYANURIC ACID IS NOT BEING TESTED) Test for cyanuric acid level at least once/week. (AT TIME OF INSPECTION THIS WAS DISCUSSED WITH THE LIFEGUARD. IT APPEARS THAT NOT ALL OF THE TOOLS NEEDED TO TEST FOR CYANURIC ACID IS AVAILABLE. MAKE SURE TOOLS ARE AVAILABLE TO BE ABLE TO TEST CYANURIC ACID AT LEAST ONCE PER WEEK) |
3701-31-04 (B)(6)(i) A means of determining rate-of-flow was not found for all water pumps. (AT TIME OF INSPECTION THE METER APPEARS TO BE STUCK) Properly install a flow meter or have a pump curve available for every water pump used for the pool. (REPAIR/REPLACE FLOW METER) |
Comments |
---|
Paint is peeling from the bottom of the pool, recommend repairing. |