Inspection Information | Facility Name: | CANTERBURY SWIM & TENNIS CLUB WADING POOL |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 19-July-2021 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(4)(a)(ii) Combined chlorine was not tested daily at pool side prior to use. Combined chlorine was not documented on daily testing records. Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the combined chlorine must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use. |
3701-31-04 (B)(4)(a)(vi) Total alkalinity was not tested weekly. Some weeks did not have total alkalinity recorded. Test total alkalinity at least once/week. |
3701-31-04 (B)(4)(a)(vii) Cyanuric acid was not tested weekly. Some weeks did not have the cyanuric acid recorded on the records. Test for cyanuric acid level at least once/week. |
Comments |
---|
Attempted inspection. Pool was closed due to equipment failure. Manager unsure if pool will reopen this year. |