Inspection Information | Facility Name: | LAKEVIEW POOL & TENNIS CLUB |
---|---|
Facility Type: | Special Use |
[?] Inspection type: | Standard |
Inspection date: | 15-August-2014 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(1)(c) Critical Chlorine disinfectant residual was less than 1 ppm for the pool Do not operate the pool when the disinfectant residuals are less than what is required. Ensure the chlorine disinfectant residual is at 1 ppm or above prior to placing the pool back into operation. |
3701-31-04 (B)(4)(a)(i) Disinfection residuals were not tested before the pool was opened Test the disinfection residual every day before bathers enter the water. If an automatic chemical controler is in use the disinfectant residual must be tested every 12 hours while the pool is in use. |
3701-31-04 (B)(4)(a)(iii) pH was not tested before opening the pool. pH must be tested prior to bathers entering the water and pH must be tested every 12 hours while the pool is in use. |
3701-31-04 (C)(3) Total alkalinity was 30 ppm. Raise the total alkalinity to at least 60 ppm. |