Inspection Information | Facility Name: | MT. BLANCHARD ISLAND PARK POOL |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 25-June-2020 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(4)(a)(ii) Combined chlorine was not tested daily at pool side prior to use. Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the combined chlorine must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use. |
3701-31-04 (B)(4)(a)(vii) Cyanuric acid was not tested weekly. Test for cyanuric acid level at least once/week. |
Comments |
---|
Ensure that the automatic chemical controller (ACC) is tested monthly and marked on the daily log (there is a spot on the chart for this) Emergency equipment is available: spine board, life bouy, shepards crook, emergency phone and first aid kit. |