Inspection Information | Facility Name: | RIVERSIDE PARK - SPLASH |
---|---|
Facility Type: | Special Use |
[?] Inspection type: | Pre-Licensing |
Inspection date: | 24-May-2019 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(6)(h) Required meters and gauges were not maintained or were not functional while the pool is in operation. Flow meter is not operational. Maintain all meters and gauges in a properly funtioning manner at all times while the pool is in operation. |
3701-31-04 (C)(2) pH was outside the range of 7.2 to 7.8. pH is at 6.8 or lower Treat the pool water so that the pH is within the acceptable range. |
3701-31-04 (C)(3) Repeat Total alkalinity was less than 60 ppm. Alkalinity is at 30 ppm. Raise the total alkalinity to at least 60 ppm. |
3701-31-04 (E)(2)(e) Emergency device (telephone) was not working. Have phone repaired. Ensure that the emergency device is functioning properly and rings to the emergency response authorities. |
Comments |
---|
Adjust water chemistry and repair flow meter. Ok to open. Cell phone on site for temporary emergency phone. |