Inspection Information | Facility Name: | FINDLAY FAIRFIELD INN & SUITES |
---|---|
Facility Type: | Pool |
[?] Inspection type: | Standard |
Inspection date: | 19-September-2016 |
Violations: A summary of the violations found during the inspection are listed below. |
3701-31-04 (B)(6) Flow meter is not installed in an acceptable location. Install the flow meter in a location that has 10x the pipe diameter upstream and 5x the pipe diameter downstream of straight, unobstructed flow |
3701-31-04 (B)(6)(c)(ii) Repeat Backwash lines and lines from drainage sumps did not have an air gap prior to discharge Open the lines that discharge into the backwash or drainage sumps so that there is an air gap and the lines can drain freely. |
Comments |
---|
Flow switch tested at time of inspection. Make sure to test and record flow switch monthly. A new pump and motor have been installed for circulation of pool. Submit ERN to Ohio Department of Health for approval of new pump. New main drains covers and skimmer equalizer line covers have been installed. |