3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical The minimum disinfection residual was not maintained as required. At pool-side, the disinfection residual was measured at 0.5 ppm.
Maintain the minimum disinfection residual of 1 ppm or greater as required. Do not open the pool to swimmers until the minimum disinfection residual has been restored. Correct By: 02-Aug-2016
3701-31-04 (B)(6)(r) / Safety line(s) are maintained
Corrected During Inspection Safety line(s) were not maintained in place.
Safety lines must be in place when required to alert the bathers of the change in depth of the pool.
Facility Type: Pool
Inspection Type: Standard
Inspection Date: 01-August-2016
Comments |
---|
The automatic chemical control unit has both an audio and visual alarm that has been activated. Maintain a disinfection residual of 1 ppm or greater as required. Do not open the pool to swimmers until the minimum disinfection residual is restored. Please contact our office prior to reopening the pool. Pool Operator has been provided with information to post regarding RWI prevention. |