3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Ladders/stairs/steps were not in good repair or were not slip resistant. Hand rail on shallow end stairs is bvery loose and needs to be secured.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair.
3701-31-04 (D)(05) / Cyanuric acid level shall not exceed 70 ppm.
Cyanuric acid level exceeded 70 ppm. Cyanuric acid was tested at 100 ppm at time of inspection.
Drain the pool at least halfway and fill with clean water. Monitor the amount of cyanuric acid being used and adjust accordingly.
Facility Type: Pool
Inspection Type: Standard
Inspection Date: 25-July-2017
Comments |
---|
Pool is still in the same condition (chipped paint, cracking concrete). Facility has plans to make repairs once the pool season is over. |