3701-31-04 (B) / All facilities are maintained clean, safe and sanitary condition and in good repair.
Observed deteriorated surfacing on diving boards. Observed general concrete repairs needed at pool deck, especially along the perimeter of the gutters in the shallow end. Observed some build up/staining on pool floor.
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Observed loose pool ladders at 3ft depth and at 5ft depth beside lifeguard post.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
At time of inspection, observed pH of pool water at 8.0 or greater. Operator to begin feeding sulfuric acid.
3701-31-04 (E)(2)(a)(i) / 12 ft. non-telescopic reach pole with shepherd's crook is provided
Currently, the shepherd's crook provided is telescopic. Operator is working to order a non-telescopic shepherd's crook.
Facility Type: Pool
Inspection Type: Standard
Inspection Date: 10-June-2022
Comments |
---|
Compliant well water sample for total coliform bacteria needs to be provided at time of next standard inspection. |