3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
Repeat ORP reading was observed at 585 mv. Have the ACC unit inspected to determined why the ORP is low.
3701-31-04 (B) / All facilities are maintained clean, safe and sanitary condition and in good repair.
Repeat Observed a return outlet missing a cover on the bottom of the pool.
3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Repeat No paperwork was available upon request for the main drain cover. Spoke with management who stated the drain cover will be replaced that meets the requirements prior to opening next season.
3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical Repeat The chlorine residual in the pool was tested/observed to be 0 ppm. The operator voluntarily closed the pool until disinfectant residuals can be brought up to the minimum standard.
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Repeat Hand rail by steps observed loose. Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair.
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Repeat Entry gate to pool area observed unable to self-latch. Ensure the gate can self latch to prevent unauthorized entry into the pool area.
3701-31-04 (E)(3)(b) / "Children must be supervised" or "Swimming alone is not recommended" signs posted
Repeat The unguarded pool was in use without the "Children must be supervised" and/or "Swimming alone is not recommended" signs posted. Post the "Children must be supervised" and/or "Swimming Alone is Not Recommended" signs at all times the pool is available for use.
3701-31-04 (E)(3)(d) / "WARNING or DANGER - POOL CLOSED" sign(s) posted-when the pool is closed
Repeat Upon closure of the pool the operator stated that the facility did not have a "WARNING or DANGER - POOL CLOSED" sign to post. Post the "WARNING or DANGER - POOL CLOSED" sign at all times the pool is not available for use.
Facility Type: Pool
Inspection Type: Follow-up
Inspection Date: 26-August-2022
Comments |
---|
Chlorine observed at 10 ppm, pool is permitted to operate as usual. |