3701-31-04 (B) / All facilities are maintained clean, safe and sanitary condition and in good repair.
Observed paint surfacing wear on pool bottom.
3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical Corrected During Inspection 0 ppm free chlorine upon testing during inspection. Operator voluntarily closed pool to raise level of chlorine and refilled bulk disinfectant container on-site.
3701-31-04 (B)(4)(a)(v) / Water clarity are not present
Water clarity determination not being recorded on daily operation log.
Record water clarity determination on daily operation log.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8, as it was tested at 8.0.
Treat the pool water so that the pH is within the acceptable range.
Facility Type: Pool
Inspection Type: Standard
Inspection Date: 04-June-2021
Comments |
---|
Operator voluntarily closed the activity pool on-site and hand-dosed chlorine into the pool and refilled bulk disinfectant container as delivery was in progress during inspection. Chlorine level was raised to 3 ppm on-site prior to inspection completing and pool was opened. |