3701-31-04 (B) / All facilities are maintained clean, safe and sanitary condition and in good repair.
Repeat Not tempered water supplied to hand washing sinks in restrooms.
3701-31-04 (B)(4)(a)(iv) / Water temperatures are recorded daily
Repeat Water temperatures were not being recorded daily.
Take and record the water temperature at least once/day.
3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Repeat Required turnover rates were not met. Flow rate observed at 950 gpm and the minimum flow rate is 1042 gpm.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve.
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Repeat Loose ladders observed around the pool deck as they were missing bolts to secure ladders to deck.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair.
3701-31-04 (E)(2)(b)(i) / 12 ft. non-telescopic reach pole with Sheppard's crook & a USCG Type IV personal flotation device with 30 - 60 foot throw line.
12 ft. non-telescopic reach pole with Shepherd's crook not provided at pool.
Provide the non-telescopic reach pole and personal floatation device at the pool at all times.
3701-31-04 (E)(4)(b) / Written plan for lifeguard coverage available for all pools 6,000 sq. ft or larger
Repeat The written lifeguard coverage plan was not available for review for pools 6,000 sq. ft or larger.
Prepare and provide a written lifeguard coverage plan that contains all the required elements according to the rule. The plan must be available for review upon request.
Facility Type: Pool
Inspection Type: Standard
Inspection Date: 28-July-2021