3701-31-04 (B)(1)(g) / Water clarity shall be sufficient to see the pool bottom (or Secchi disc).
Critical Water clarity was not sufficient to see the main drain cover.
Do not operate the pool when water clarity is poor. Correct By: 16-Jun-2015
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Flow meter was not functional while the pool was in operation.
Maintain all meters and gauges in a properly funtioning manner at all times while the pool is in operation. Correct By: 29-Jun-2015
3701-31-04 (D)(09) / Chemicals shall not be manually added to pool when bathers present.
Chemicals were manually added to the pool skimmers.
Stop adding chemicals to the skimmers. Correct By: 29-Jun-2015
3701-31-04 (E)(3)(b) / "Children must be supervised" or "Swimming alone is not recommended" signs posted
The unguarded pool was in use without the "Swimming alone is not recommended" sign posted.
Post the "Swimming Alone is Not Recommended" sign at all times the pool is available for use. Correct By: 29-Jun-2015
Facility Type: Pool
Inspection Type: Standard
Inspection Date: 15-June-2015