3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. Skimmers are missing the weirs.
All equipment must be maintained in accordance with the manufacturers specifications.
REPLACE THE MISSING WEIRS IN THE SKIMMERS.
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Repeat Gates or doors were not self-closing and lockable.
Repair gates or doors in order to be self-closing and lockable.
ADJUST THE GATE SO THAT IT CLOSES AND SELF-LATCHES
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 07-June-2023
Comments |
---|
Our records show that the main drain suction outlet covers (AquaStar WAV12) were installed 6/1/2019. The covers have a 5 year life span and must be replaced before 6/1/2024. One of the filters is leaking from the cap. Please look into replacing the ring buoy . When using CYA (cyanuric acid) the alkalinity level is calculated by subtracting 1/3 the CYA level from the alkalinity reading. EXAMPLE: alkalinity test reading = 70 ppm, CYA = 60 ppm. Alkalinity is 70 ppm – (60/3) = 50 ppm The operator was observed performing onsite chemical tests appropriately |