[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Outlet covers were not installed. The skimmer equalizer outlets are not covered with a compliant cover or plugged.
Do not operate the pool when the outlet covers are not installed. INSTALL VGB COMPLIANT COVERS OVER THE SKIMMER EQUALIZER OUTLETS OR PLUG THE OUTLETS AT THE POOL WALL. Correct By: 01-Jul-2021

3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Ladders/stairs/steps were not in good repair or were not slip resistant. The handrail to the steps is loose
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair. TIGHTEN THE HANDRAIL TO THE STEPS. Correct By: 01-Jul-2021
3701-31-04 (E)(2)(a)(i) / 12 ft. non-telescopic reach pole with shepherd's crook is provided
12 ft. non-telescopic reach pole with shepherd's crook was not provided at the unguarded pool. The pole was telescopic
Provide a 12 ft. non-telescopic reach pole in the pool area at all times. MAKE THE REACH POLE NON-TELESCOPIC OR SWITCH THE SHEPHERD'S CROOK TO A 12 FT NON-TELESCOPIC POLE. Correct By: 01-Jul-2021


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 29-June-2021


Comments
The Certificate of Compliance for the main drain cover is available in the equipment room.

Our records show that the main drain suction outlet covers (AquaStar 8 MF) were installed on 5-23-19. The covers have a 5 year life span and must be replaced before 5-23-24.

A SIGN STATING "SWIMMING ALONE IS NOT RECOMMENDED" WAS NOT SEEN. POST THIS SIGN IF NOT ALREADY UP.

IF OR WHEN THE FLOW METER IS REPLACED, INSTALL THE NEW FLOW METER ON THE LONG STRAIGHT SECTION OF THE PIPE LOCATED ALONG THE BACK WALL SO THAT THE INSTALLATION CAN CONFORM TO THE MANUFACTURER'S REQUIREMENT OF PLACING IT 10 TIMES THE DIAMETER PIPE DOWN STREAM FROM AN ELBOW (OR TURBULENCE) AND 5 TIMES THE DIAMETER OF THE PIPE UPSTREAM FROM AN ELBOW.