[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6)(c)(i) / Backflow prevention devices shall be maintained.
Backflow prevention devices were not in place on the three hose bibs.
Have the backflow prevention devices installed so that backflow is prevented. INSTALL ASSE 1011 BACKFLOW PREVENTERS ON THE THREE HOSE BIBS. TWO IN THE EQUIPMENT ROOM AND ONE OUTSIDE THE EQUIPMENT ROOM DOOR. Correct By: 13-Jun-2019
3701-31-04 (E)(2)(d) / First aid kit provided
First aid equipment was not provided.
Provide first aid equipment, including a first aid kit, at the pool at all times. Correct By: 13-Jun-2019


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 06-June-2019


Comments
Our records show: The main drain suction outlet cover (AquaStar 8MF) was installed 8/22/2014. The cover has a 5 year life span and must be replaced before 8/22/2019.

-It is recommended that the rope on the ring buoy be untangled so it can be used in an emergency.
-The bottom of the fence can be lifted up to gain entry. A stringer should be installed on the bottom of the fence to prevent entry under the fence.