3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical Repeat Chlorine disinfectant residual was less than 1 ppm for the pool
Do not operate the pool when the disinfectant residuals are less than what is required. Ensure the chlorine disinfectant residual is at 1 ppm or above prior to placing the pool back into operation.
THE OPERATOR WAS CONTACTED AND INFORMED OF THE CRITICAL OPERATING ITEM. SWIMMERS WERE INFORMED OF THE IMMINENT HEALTH HAZARD AND ADVISED NOT TO USE THE POOL, Correct By: 06-Jul-2023
3701-31-04 (B)(1)(e) / Automatic Chemical Controller (ACC) shall function properly.
Critical Automatic Chemical Controller (ACC) was not functioning properly at the time of the inspection
Do not operate the pool when the ACC unit is not functioning properly. Ensure that the ACC unit is functioning properly prior to placing the pool back into operation.
THIS IS A CRITICAL OPERATIONAL ITEM AND POSES AN IMMINENT HEALTH HAZARD. THE POOL MUST CLOSE UNTIL THE CHEMICAL FEEDER IS WORKING PROPERLY. Correct By: 06-Jul-2023
3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Repeat Chemical containers were stored without labels identifying the contents.
Label and properly store all chemical containers to avoid a chemical reaction or unnecessary exposure.
LABEL THE ACID TANK.
3701-31-04 (D)(02) / Public swimming pool is continuously disinfected using a chemical feeding device connected to the circulation system
Critical The pool was not being continuously disinfected using a chemical feeding device connected to the circulation system
Repair or replace the disinfection system so that the pool is continuously being disinfected.
HAND FEEDING CHLORINE TO MAINTAIN CHLORINE LEVELS IS NOT PERMITTED. DO NOT OPEN THE POOL UNTIL THE AUTOMATIC CHLORINE PUMP IS FUNCTIONING. Correct By: 06-Jul-2023
3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
Repeat ORP reading was below 650 mv
Have the ACC unit inspected to determined why the ORP is low. Correct By: 07-Jul-2023
3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired.
INCREASE THE FLOW RATE TO AT LEAST 126 GPM. Correct By: 07-Jul-2023
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Repeat Gates or doors were not self-closing and lockable.
Repair gates or doors in order to be self-closing and lockable.
ADJUST THE GATE SO THAT IT SELF-CLOSES.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 06-July-2023