[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical The operator does not have any information about the drain covers: age, make or model.
OBTAIN THE CERTIFICATE OF COMPLIANCE, THE INSTALLATION INSTRUCTIONS AND THE DATE OF INSTALLATION OR REPLACE THE COVERS WITH COMPLIANT COVERS AND RETAIN THE ABOVE DOCUMENTATION ALONG WITH THE CERTIFICATE OF INSTALLATION (BLANK COPY SUPPLIED TO OPERATOR). Correct By: 02-Jul-2017
3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical The equalizer outlets do not have compliant covers.
INSTALL COMPLIANT COVERS ON THE EQUALIZER OUTLETS OR PLUG THE EQUALIZER OUTLETS AT THE POOL WALL. Correct By: 02-Jul-2017

3701-31-04 (B)(6)(c)(i) / Backflow prevention devices shall be maintained.
Backflow prevention devices were not maintained to function properly. The hose bib used to fill the pool does is not back flow protected.
Have the backflow prevention device evaluated or replaced so that backflow is prevented. INSTALL A ASSE 1011 BACKFLOW PREVENT ON THE HOSE BIB THAT IS USED TO FILL THE POOL. Correct By: 09-Jun-2017
3701-31-04 (B)(6)(c)(ii) / Backwash lines and lines from drainage sumps shall have an air gap and remain open to freely drain.
The backwash line to the sump pit does not have an air gap.
PROVIDE AN AIR GAP ON THE BACKWASH DRAIN LINE. Correct By: 09-Jun-2017
3701-31-04 (B)(6)(i) / A means of determining rate-of-flow on all water pumps
The flow meter is located 4 inches upstream from an elbow in the 2 inch pipe.
RELOCATE THE FLOW METER AT LEAST TIMES THE DIAMETER OF THE PIPE DOWN STREAM FROM THE NEAREST TURBULENCE AND AT LEAST 5 TIMES THE DIAMETER OF THE PIPE UP STREAM FROM THE NEAREST TURBULENCE. Correct By: 02-Jul-2017
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Ladders/stairs/steps were not in good repair or were not slip resistant. The hand rail at the steps was loose. The ladder was not installed.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair. TIGHTEN THE HAND RAIL AND INSTALL THE LADDER. Correct By: 09-Jun-2017
3701-31-04 (B)(6)(q) / Depth markers/deck warning signs are maintained
Depth markers/deck warning signs were not maintained in a clearly legible/visible manner. The depth markers are more than 25 ft apart at the deep end.
Replace the depth markers/deck warning signs so that bathers are able to clearly see the depth of the water and that no diving is permitted where clearly indicated. PROVIDE AN ADDITIONAL DEPTH MARKER WHERE THEY ARE SPACED MORE THAN 25 FT APART AND REPAINT THE FADED DEPTH MARKERS AND NO DIVING SIGNS ON THE DECK. Correct By: 09-Jun-2017
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
The gate does not self close.
REPAIR THE GATE SO IT SELF CLOSES. Correct By: 09-Jun-2017
3701-31-04 (D)(8) / Acceptable test kit provided/adequate/in good repair
The pool test kit reagents are expired.
OBTAIN A NEW TEST KIT WITH FRESH REAGENTS. Correct By: 09-Jun-2017
3701-31-04 (E)(2)(b)(i) / 12 ft. non-telescopic reach pole with Sheppard's crook & a USCG Type IV personal flotation device with 30 - 60 foot throw line.
The reach pole with the shepherds crook is only 8 ft long.
PROVIDE A REACH POLE THAT IS 12 FT LONG WITH A SHEPHERDS CROOK. Correct By: 09-Jun-2017
3701-31-04 (E)(2)(d) / First aid kit provided
First aid equipment was not provided. The supplies in the first aid kit are depleted.
Provide first aid equipment, including a first aid kit, at the pool at all times. RESTOCK THE FIRST AID KIT WITH GLOVES, GAUZE, AND BANDAGES TO ADDRESS CUTS AND BLEEDING. Correct By: 09-Jun-2017


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 02-June-2017


Comments
"PROVIDE A "WARNING POOL CLOSED" SIGN FOR WHEN THE POOL IS CLOSED.