3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical Chlorine disinfectant residual was less than 1 ppm for the pool
Do not operate the pool when the disinfectant residuals are less than what is required. Ensure the chlorine disinfectant residual is at 1 ppm or above prior to placing the pool back into operation.
THIS VIOLATION POSES AN IMMINENT HEALTH HAZARD. THE POOL MUST CLOSE UNTIL THE VIOLATION IS CORRECTED. FREE CHLORINE LEVEL MUST BE AT LEAST 1 PPM BEFORE REOPENING. THE POOL ATTENDED HAS ALL SWIMMERS EXIT THE POOL AND THE MANAGER WAS CONTACTED FOR REPAIRS.
CALL THE HEALTH DEPARTMENT AT 440-219-7158 WHEN CORRECTED. Correct By: 06-Jul-2021
3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical Equipment/chemical/storage areas were not secured.
These storage areas must be kept inaccessible to everyone but authorized personnel. Secure the areas.
KEEP EQUIPMENT ROOM LOCKED. Correct By: 08-Jul-2021
3701-31-04 (B)(3) / Staff is trained and knowledgeable
Staff was not trained or knowledgeable in pool operations. The records indicated that the free chlorine level was 0ppm for the last 3 days, but the pool was open.
Train staff in pool operations, operation of equipment, chemical storage, use and handling and appropriate emergency procedures.
TRAIN STAFF ON WHAT ARE CRITICAL OPERATING ITEMS AND WHEN THE POOL MUST CLOSE. Correct By: 08-Jul-2021
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
ADJUST pH Correct By: 08-Jul-2021
3701-31-04 (D)(05) / Cyanuric acid level shall not exceed 70 ppm.
Cyanuric acid level exceeded 70 ppm
Drain the pool at least halfway and fill with clean water. Monitor the amount of cyanuric acid being used and adjust accordingly.
LOWER CYA LEVEL TO 70 OR BELOW. Correct By: 08-Jul-2021
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Emergency device (telephone) was not working. One battery was dead.
Ensure that the emergency device is functioning properly and rings to the emergency response authorities.
REPLACE DEAD BATTERY TO THE EMERGENCY PHONE. Correct By: 08-Jul-2021
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 06-July-2021