[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(e) / Automatic Chemical Controller (ACC) shall function properly.
Critical Automatic Chemical Controller (ACC) was not functioning properly at the time of the inspection. The flow switch safety device does not turn off the chemcial feeder when there is no flow.
Do not operate the pool when the ACC unit is not functioning properly. Ensure that the ACC unit is functioning properly prior to placing the pool back into operation. THIS IS A CRITICAL OPERATION ITEM AND POSES AN IMMENIENT HEALTH HAZARD. THE OPERATOR INDICATED ON THE WEEKLY LOG SHEET THAT THIS SAFETY FEATURE IS CHECKED WEEKLY. HOWEVER, THE FLOW SWITCH DID NOT WORK LAST MOUNTH AND DOES NOT WORK AT THE TIME OF INSPECTION. THIS NEEDS TO BE REPAIRED IMMEDIATELY.

3701-31-04 (B)(6)(c)(i) / Backflow prevention devices are maintained
Backflow prevention devices were not maintained to function properly
Have the backflow prevention device evaluated or replaced so that backflow is prevented. HAVE THE BACKFLOW PREVENTER INSPECTED AND PROVIDE DOCUMENTATION TO THE WATER DEPARTMENT/BACKFLOW AUTHORITY AND KEEP A COPY AT THE POOL FACILITY. Correct By: 22-Jul-2022
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Required meters and gauges were not maintained or were not functional while the pool is in operation.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation. REPAIR THE PRESSURE GAUGE ON THE FILTER. Correct By: 22-Jul-2022
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Repeat Ladders/stairs/steps were not in good repair or were not slip resistant.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair. TIGHTEN THE HAND RAILS AND LADDERS.
3701-31-04 (E)(2)(b)(i) / 12 ft. non-telescopic reach pole with Sheppard's crook & a USCG Type IV personal flotation device with 30 - 60 foot throw line.
Repeat 12 ft. non-telescopic reach pole with Shepherd's crook was not provided at the guarded pool.
Provide the non-telescopic reach pole at the pool at all times. PROVIDE A REACH POLE WITH A SHEPHERD'S CROOK.
3701-31-04 (E)(2)(d) / First aid kit provided
Repeat First aid equipment was not provided.
Provide first aid equipment, including a first aid kit, at the pool at all times. MADE AVAILABLE A FIRST AID KIT THAT CAN BE ACCESSED.


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 15-July-2022