[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve. INCREASE THE FLOW RATE TO BETWEEN 56 TO 98 GPM
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
There is no fence around the wading pool.
INSTALL A FENCE AROUND THE WADING POOL. SUBMIT PLANS TO ODH FOR APPROVAL FIRST


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 14-August-2019


Comments
The pool was not open at the time of inspection