3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical The free chlorine level is .6.
THIS IS A CRITICAL OPERATIONAL ITEMS AND POSES AN IMMEDIATE HEALTH HAZARD. THE POOL MUST CLOSE UNTIL THE FREE CHLORINE LEVEL REACHES AT LEAST 1.0 PPM. THE POOL WAS CLOSED AT THE TIME OF INSPECTION.
3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
Repeat ORP reading was below 650 mv
Have the ACC unit inspected to determined why the ORP is low.
3701-31-04 (B)(4) / The licensee /authorized representative is keeping records
Repeat The licensee /authorized representative was not keeping or maintaining operational records.
All facility records must be maintained and available for review upon request.
KEEP TOTAL, FREE AND COMBINE CHLORINE READINGS, TEMPERATURE, AND AUTOMATIC CHEMICAL CONTROL FLOW SWITCH FUNCTION TEST RESULTS.
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. The skimmer is missing a weir.
All equipment must be maintained in accordance with the manufacturers specifications.
REPLACE THE WEIR IN THE SKIMMER.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 30-October-2018